CItpTcTimerMtp2T04E
Proving period timer emergency timer. The default and valid range is dependant on the value of variant. This timer is only applicable if cItpTcLinkType is serial. A get on this object will return a zero if the link is not serial. Min Max Def ------ ------ ------ ANSI 540 660 600 ITU 400 600 500 The SYNTAX statement allows values for both the ANSI and ITU variants.