PowerOperType
Operational FRU Status types. valid values are: offEnvOther(1) FRU is powered off because of a problem not listed below. on(2): FRU is powered on. offAdmin(3): Administratively off. offDenied(4): FRU is powered off because available system power is insufficient. offEnvPower(5): FRU is powered off because of power problem in the FRU. for example, the FRU's power translation (DC-DC converter) or distribution failed. offEnvTemp(6): FRU is powered off because of temperature problem. offEnvFan(7): FRU is powered off because of fan problems. failed(8): FRU is in failed state. onButFanFail(9): FRU is on, but fan has failed. offCooling(10): FRU is powered off because of the system's insufficient cooling capacity. offConnectorRating(11): FRU is powered off because of the system's connector rating exceeded. onButInlinePowerFail(12): The FRU on, but no inline power is being delivered as the data/inline power component of the FRU has failed.
Possible values
12 objects| Number | Name |
|---|---|
| 1 | offEnvOther |
| 2 | on |
| 3 | offAdmin |
| 4 | offDenied |
| 5 | offEnvPower |
| 6 | offEnvTemp |
| 7 | offEnvFan |
| 8 | failed |
| 9 | onButFanFail |
| 10 | offCooling |
| 11 | offConnectorRating |
| 12 | onButInlinePowerFail |