PowerOperType

  • Base type Enumeration

Operational FRU Status types. valid values are: offEnvOther(1) FRU is powered off because of a problem not listed below. on(2): FRU is powered on. offAdmin(3): Administratively off. offDenied(4): FRU is powered off because available system power is insufficient. offEnvPower(5): FRU is powered off because of power problem in the FRU. for example, the FRU's power translation (DC-DC converter) or distribution failed. offEnvTemp(6): FRU is powered off because of temperature problem. offEnvFan(7): FRU is powered off because of fan problems. failed(8): FRU is in failed state. onButFanFail(9): FRU is on, but fan has failed. offCooling(10): FRU is powered off because of the system's insufficient cooling capacity. offConnectorRating(11): FRU is powered off because of the system's connector rating exceeded. onButInlinePowerFail(12): The FRU on, but no inline power is being delivered as the data/inline power component of the FRU has failed.

Possible values

12 objects
Number Name
1 offEnvOther
2 on
3 offAdmin
4 offDenied
5 offEnvPower
6 offEnvTemp
7 offEnvFan
8 failed
9 onButFanFail
10 offCooling
11 offConnectorRating
12 onButInlinePowerFail