cds1AlarmThresholdGroupTable
The DS1 alarm threshold configuration table. This table contains the objects associated with threshold values for different statistics. The thresholds may be configured for: BES - Bursty Errored Seconds CSS - Controlled Slip Seconds DM - Degraded Minutes ES - Errored Seconds LCV - Line Code Violations LES - Line Errored Seconds LSES - Line Severely Errored Seconds PCV - Path Coding Violations PSAS - Path SEF/AIS Second SES - Severely Errored Seconds SEFS - Severely Errored Framing Seconds UAS - Unavailable Seconds