sysReset

deprecated
  • 1.3.6.1.4.1.9.5.1.1.9
  • Access readwrite
  • Type other(1), reset(2), resetMinDown(3)

Writing reset(2) to this object resets the control logic of all modules in the system. Writing resetMinDown(3) to this object resets the system with the minimal system down time. The resetMinDown(3) is only supported in systems with redundant supervisors. This object is deprecated and replaced by csyScheduledReset in CISCO-SYSTEM-MIB.

This OID is also declared by other modules: CISCO-STACK-MIB

Details

Possible values
1 other
2 reset
3 resetMinDown

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.9.5.1.31.2.1 systemMiscGroup

Comments