hpicfPoePowerRedundancy

deprecated
  • 1.3.6.1.4.1.11.2.14.11.1.9.1.4
  • Access readwrite
  • Type none(1), nPlus1(2), full(3)

This object is used to configure the POE power redundancy mode. A value of none(1) - means that all available power can be allocated to powered devices. A value of nPlus1(2) - means that one of the highest power supplies is held in reserve and that in the event of a single power supply failure, no no powered devices will be shut down. A value of full(3) - means that half of the available power supplies are held in reserve. The default value is none(1). In a stack, this value pertains only to the commander switch.

This OID is also declared by other modules: HP-ICF-POE-MIB

Details

Possible values
1 none
2 nPlus1
3 full

Used by conformance groups

1 objects
  • 1.3.6.1.4.1.11.2.14.11.1.9.1.2.2.2 hpicfPoeGlobalGroup

Comments