cOpticalParamLowAlarmThresh
1.3.6.1.4.1.9.9.264.1.1.1.1.9
This object is used to set a low alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
cOpticalParameterValue goes from above the value configured in
this object to below the value configured in this object, or if
the initial value of cOpticalParameterValue is lower than the
value configured in this object. For network elements that
incorporate a soak time in the status indications, this alarm
will be indicated in the cOpticalParamAlarmStatus object only
after it persists for a period of time that equals the set soak
interval.
The severity level of this alarm is specified by the
cOpticalParamLowAlarmSev object.
When the cOpticalMonParameterType object is set to 'power'
for the receive direction and when the interface supports
alarms based on loss of light, this object specifies the
optical power threshold for declaring loss of light. Also,
when optical amplifiers are present in the network, in the
receive direction, this value may need to be configured,
since the noise floor may be higher than the minimum
sensitivity of the receiver.