cOpticalParamHighWarningThresh 1.3.6.1.4.1.9.9.264.1.1.1.1.7

This object is used to set a high warning threshold on the optical parameter being monitored. A threshold crossing condition will be indicated if the value given by cOpticalParameterValue goes from below the value configured in this object to above the value configured in this object, or if the initial value of cOpticalParameterValue exceeds the value configured in this object. For network elements that incorporate a soak time in the status indications, this threshold violation will be indicated in the cOpticalParamAlarmStatus object only after it persists for a period of time that equals the set soak interval. This threshold crossing may or may not be alarmed or reported, based on the severity level specified by the cOpticalParamHighWarningSev object.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.9.9.264.1.1.1.1 cOpticalMonEntry