The current status of to this HCCP group member.
If the RF MAC interface is Working, this
represents the status of the Working member.
active(1) : Working member is forwarding traffic.
standby(2) : Working member is blocking traffic.
If the RF MAC interface is Protect, this represents
the Protect status to this member.
active(1) : The Protect is taking over and
forwarding the traffic from this Working
member which is now blocking.
standby(2) : The Protect is standby(blocking). This
means that Working member is forwarding
traffic and thus works fine.
nonFunctional(3): This member is disabled.