ceAlarmNotifiesEnable 1.3.6.1.4.1.9.9.138.1.4.1

This object specifies a severity threshold governing the generation of ceAlarmAsserted and ceAlarmCleared notifications. For example, if the value of this object is set to 'major', then the agent generates these notifications if and only if the severity of the alarm being indicated is 'major' or 'critical'. The value of '0' disables the generation of notifications. Observe that this setting overrides the value of the ceAlarmFilterNotifiesEnabled object. This object affects notification generation only; that is, it does not affect monitoring, history logging, and syslog message generation.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.9.9.138.1.4 ceAlarmFiltering