mscVsPlcLocalAddress
1.3.6.1.4.1.562.36.2.1.80.3.10.1.21
This attribute is the PLC's end point address in the format of an
NSAP address. As such it must consist of a string of hex digits
although not all 40 digits must be specified. LocalAddress must
share a prefix with MOD nodePrefix or one of MOD
alternatePorsPrefixes for this node, otherwise PORS will not be able
to route calls to this service. LocalAddress is used in conjunction
with addressToCall. That is, the end responsible for originating
calls must have addressToCall provisioned, while the end
responsible for terminationg calls must have localAddress
provisioned. In such a case, addressToCall on the originating end
must match exactly the localAddress of the terminating end. Note
that both ends may be originating and terminating at the same time.
That is, both ends may have addressToCall and localAddress
provisioned as long as addressToCall and localAddress on different
ends are identical.