mscNSClockSyncState
1.3.6.1.4.1.562.36.2.1.20.12.1.1
When the clockSyncState is in the freeRun state, either no
reference have beed provisioned or none of the provisioned
references have been found to be valid. The Stratum-3 clock is
allowed to run freely at its last adjusted frequency. When the
clockSyncState is in the synchronizing state, the Stratum-3 is
trying to synchronize in frequency to a valid provisioned reference.
This state should last approximately 1-2 minutes, provided the
reference is stable. Once frequency synchronization is acheived, a
null phase is acquired and the clockSyncState enters the
synchronized state. In this state, both phase and frequency are
tracked and compensated for. This node is now ready to support
transparent data services.