This attribute indicates the failures that prevent the fabric port from
using the associated fabric. It may contain any combination of the
following values:
selfTest: The port has failed its self-test.
hardwareError: An unrecoverable critical error has occurred on the
hardware of the processor card which exchanges cells with fabric
card.
portProtocolError: Errors have occurred which violate the protocol
between components of the fabric port in datapath.
switchClockError: The fabric card clock is no longer detected by
the processor card.
livelinessError: A non-fatal hardware error has occurred on the
component which exchanges cells with the fabric card. Excessive
numbers of these errors on the fabric port may be indicating a
serious hardware problem.
dataCorruptionError: Cell payloads or headers are detected as
being corrupted at the fabric port level.
linkLivelinessError: The link between the fabric port and the fabric
card is not indicating liveliness.
Operator action: Run the fabric test to clear these errors.
Description of bits:
selfTest(0)
hardwareError(1)
portProtocolError(2)
switchClockError(3)
livelinessError(4)
dataCorruptionError(5)
linkLivelinessError(6)