This attribute specifies whether switch-side segment loopback
insertion should be performed on this connection.
When sameAsInterface is selected, the switch-side segment
loopback for the connection is based on the segSwitchSideLoopback
attribute of the connection's parent AtmIf componentif the ATM
interface has switch-side segment loopback insertion turned on,
then switch-side segment loopback insertion is also on for the
connection.
When on or off is selected, switch-side segment loopback insertion
is turned on or off respectively for the connection regardless of the
provisioning of the parent AtmIf component.
Note that switch-side segment loopback insertion is not possible if
the connectionPointType attribute of the Vcc or Vpc component is
connectingPoint or connectionEndPoint. Switch-side segment
loopback insertion is also not possible if the distributionType of the
Vcc is pointToMultipoint In such cases, the associated
segSwitchSideLoopbackState attribute indicates notApplicable and
switch-side segment loopback insertion is not performed. Switch-
side segment loopback is never possible on a Vpt.