mscAtmIfVpcTmRxTdpTable
1.3.6.1.4.1.562.36.2.1.114.4.9.453
This attribute is a vector of four traffic parameters whose meanings
are defined by the rxTrafficDescType attribute. The values of peak
cell rate (PCR), sustained cell rate (SCR), minimum cell rate
(MCR) are expressed in cell/s. Maximum burst size (MBS) is
expressed in cells. Cell delay variation tolerance (CDVT) is
expressed in microseconds.
When rxTrafficDescType is 1 or 2, none of the parameters are used.
When rxTrafficDescType is 3, parameter 1 represents the PCR for
CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT.
When rxTrafficDescType is 4, parameter 1 represents the PCR for
CLP equal to 0 and 1 traffic; parameter 2 represents the PCR for
CLP equal to 0 traffic with cell discard; parameter 4 represents the
CDVT.
When rxTrafficDescType is 5, parameter 1 represents the PCR for
CLP equal to 0 and 1 traffic; parameter 2 represents the PCR for
CLP equal to 0 traffic with cell tagging; parameter 4 represents the
CDVT.
When rxTrafficDescType is 6, parameter 1 represents the PCR for
CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for
CLP equal to 0 and 1 traffic; parameter 3 represents the MBS for
CLP equal to 0 and 1 traffic; parameter 4 represents the CDVT.
When rxTrafficDescType is 7, parameter 1 represents the PCR for
CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for
CLP equal to 0 traffic with cell discard; parameter 3 represents the
MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT.
When rxTrafficDescType is 8, parameter 1 represents the PCR for
CLP equal to 0 and 1 traffic; parameter 2 represents the SCR for
CLP equal to 0 traffic with cell tagging; parameter 3 represents the
MBS for CLP equal to 0 traffic; parameter 4 represents the CDVT.
When rxTrafficDescType is 9, parameter 1 represents the PCR;
parameter 2 represents CDVT; parameter 3 represents the MCR;
parameter 4 is not used.
If upc is disabled for this connection, the values of PCR, SCR,
MBS and CDVT are the provisioned parameters.
If upc is enabled, the values of PCR, SCR, MBS, and CDVT are
exactly the values used by the usage parameter control hardware in
policing the arriving traffic. These may vary slightly from the
provisioned values due to granularity of the hardware. In the case
where the PCR is equal to the SCR, the effective MBS is zero.