lpJT2ClockingSource
1.3.6.1.4.1.562.2.4.1.12.16.11.1.1
This attribute defines the source of the transmit clock for the JT2
line.
When the clocking source is selected from local, the oscillator on
the port generates the clocking for the line.
When the clocking source is selected from line, the port
synchronizes to the clock recovered from the incoming line signal.
When the clocking source is selected from module, the port's clock
synchronizes to the clock provided by the oscillator on the active
CP.
Note:- that when one port is set to local, the other port must also be
set to local, and when one port is set to module, the other port must
also be set to module. If one of the ports is set to line, the other port
must be set to otherPort.
Also, if a CP reference clock is available when the JT2 component
is added, the clocking source defaults to module, whereas if a CP
reference clock is not available when the component is added, the
clocking source defaults to local.