atmIfVptCAUbrMaxVccs 1.3.6.1.4.1.562.2.4.1.114.9.5.6.100.1.6

This attribute specifies the maximum number of UBR Vccs that can be configured associated with this Vpt. The value must not exceed the maxVccs attribute of the parent Vpt CA component. If this attribute is set to sameAsCa, the maximum number of UBR Vccs is the same as specified by the maxVccs attribute of the Vpt CA. Changes to this attribute are not critical to the Vpt. If the value is changed to a number smaller than the current number of active VCCs, no new VCCs can be admitted until the number of active VCCs drops below the value of this attribute. The current number of active VCCs is indicated by the sum of the permanentVccs and switchedVccs operational attribute under the Vpt CA component. VALUES ( 16385 = sameAsCa )

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.562.2.4.1.114.9.5.6.100.1 atmIfVptCAUbrProvEntry