atmIfVptVpdTmAbrInitialCellRate
1.3.6.1.4.1.562.2.4.1.114.9.2.2.2.110.1.10
This attribute specifies the Initial Cell Rate (ICR) parameter for this
connection. ICR is the rate at which a source should send initially
and after an idle period.
When this attribute is set to sameAsCa, the initial cell rate is
determined by the AtmIf CA Abr/0 icr attribute. When the value of
this attribute is set to useMcr, ICR is set to the same value as the
Minimum Cell Rate (MCR) for the connection.
When the value of this attribute is set to usePcr, ICR is set to the
same value as the Peak Cell Rate (PCR) for the connection.
If this attribute is specified less than the MCR of the connection,
then the MCR is used as the ICR. If this attribute is specified more
than PCR of the connection, then PCR is used as the ICR.
This attribute is ignored under all conditions where the operational
attribute abrConnectionType indicates erSwitch or efciSwitch.
VALUES (
16777216 = sameAsCa
16777217 = useMcr
16777218 = usePcr
)