atmIfCAAbrAcrDecreaseTimeFactor 1.3.6.1.4.1.562.2.4.1.114.3.5.100.1.29

This attribute specifies the default Allowed Cell Rate Decrease Time Factor (ADTF) parameter for ABR connections. An override to this default may be specified for a provisioned connection under the Vcd Tm Abr or Vpd Tm Abr component, or signalled in the ABR Additional Parameters Information Element. ADTF is the time interval permitted between sending forward Resource Management (F-RM) cells before the Allowed Cell Rate (ACR) is decreased to the Initial Cell Rate (ICR). In other words, if the source does not transmit a forward RM cell for a period of ADTF centi-seconds (hundredths of a second), it will reduce its ACR to the value of its ICR. If ACR is already at or below ICR, further rate reductions are defined by the CRM ABR parameter.

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.562.2.4.1.114.3.5.100.1 atmIfCAAbrProvEntry