frxMgtT392 1.3.6.1.4.1.1570.1.5.1.1.3

This controls how long (in seconds) the channel unit will wait for a subscriber to send it an Annex-D poll before declaring a link error from the subscriber. This is the Annex-D T392 parameter (Typical value 15)

Informations

Access Type
readwrite

Parent

1.3.6.1.4.1.1570.1.5.1.1 frxMgtEntry