MIB Explorer
beta
Explorer
What's SNMP ?
Use SNMP client
CTRON-SSR-HARDWARE-MIB
This module defines a schema to access SSR hardware configuration.
MIB content
(37 objects)
1.3.6.1.4.1.52.2501.1.1
sysHwGroup
1.3.6.1.4.1.52.2501.1.200
hardwareMIB
1.3.6.1.4.1.52.2501.1.200.2
hwConformance
1.3.6.1.4.1.52.2501.1.200.2.1
hwCompliances
1.3.6.1.4.1.52.2501.1.200.2.2
hwGroups
1.3.6.1.4.1.52.2501.1.1.1
sysHwNumSlots
1.3.6.1.4.1.52.2501.1.1.4
sysHwPowerSupply
1.3.6.1.4.1.52.2501.1.1.5
sysHwFan
1.3.6.1.4.1.52.2501.1.1.6
sysHwTemperature
1.3.6.1.4.1.52.2501.1.1.7
sysHwChassisId
1.3.6.1.4.1.52.2501.1.1.10
sysHwTotalInOctets
1.3.6.1.4.1.52.2501.1.1.11
sysHwTotalOutOctets
1.3.6.1.4.1.52.2501.1.1.12
sysHwTotalInFrames
1.3.6.1.4.1.52.2501.1.1.13
sysHwTotalOutFrames
1.3.6.1.4.1.52.2501.1.1.14
sysHwTotalL2SwitchedFrames
1.3.6.1.4.1.52.2501.1.1.15
sysHwTotalL3SwitchedFrames
1.3.6.1.4.1.52.2501.1.1.19
sysHwSwitchingFabric
1.3.6.1.4.1.52.2501.1.1.20
sysHwControlModuleLED
1.3.6.1.4.1.52.2501.1.1.21
sysHwControlModuleBackupState
1.3.6.1.4.1.52.2501.1.1.22
sysHwLastHotSwapEvent
1.3.6.1.4.1.52.2501.1.1.2
sysHwModuleTable
1.3.6.1.4.1.52.2501.1.1.3
sysHwPortTable
1.3.6.1.4.1.52.2501.1.1.2.1
sysHwModuleEntry
1.3.6.1.4.1.52.2501.1.1.3.1
sysHwPortEntry
1.3.6.1.4.1.52.2501.1.1.2.1.1
sysHwModuleSlotNumber
1.3.6.1.4.1.52.2501.1.1.2.1.2
sysHwModuleType
1.3.6.1.4.1.52.2501.1.1.2.1.3
sysHwModuleDesc
1.3.6.1.4.1.52.2501.1.1.2.1.4
sysHwModuleNumPorts
1.3.6.1.4.1.52.2501.1.1.2.1.5
sysHwModuleVersion
1.3.6.1.4.1.52.2501.1.1.2.1.6
sysHwModuleMemory
1.3.6.1.4.1.52.2501.1.1.2.1.8
sysHwModuleService
1.3.6.1.4.1.52.2501.1.1.2.1.9
sysHwModuleStatus
1.3.6.1.4.1.52.2501.1.1.3.1.1
sysHwPortSlotNumber
1.3.6.1.4.1.52.2501.1.1.3.1.2
sysHwPortNumber
1.3.6.1.4.1.52.2501.1.1.3.1.3
sysHwPortType
1.3.6.1.4.1.52.2501.1.1.3.1.4
sysHwPortConnectorType
1.3.6.1.4.1.52.2501.1.1.3.1.5
sysHwPortIfIndex
Informations
Organization
Cabletron Systems, Inc.
Contact info
Enterasys Networks 35 Industrial Way, P.O. Box 5005 Rochester, NH 03867-0505 (603) 332-9400 support@enterasys.com http://www.enterasys.com
Revisions
2000-07-17 00:00
Add support for the Smart Switch 6000 2 Port Gigabit Backplane module to the SSRModuleType for the Enterasys SSR product line
2000-07-15 00:00
Update contact information. This mib is found on Riverstone Networks RS product line as well as Enterasys SSR product line
2000-05-31 00:00
Modify SSRPortConnectorType for GBIC connector in 4.0 and update sysHwModuleService by appending the board serial number for 4.0 for RS-32000.
2000-03-20 00:00
Add Firmware 4.0 support. 3200 series modules, gigabit modules with GBIC support.
1999-12-30 00:00
Add Firmware 3.1 support. 16 port 10/100 TX, Gigabit over Copper, ATM OC-3, POS OC3/12.
1999-01-20 00:00
Add Firmware 3.0 support. Add Backup control module status and last Hotswap event.
1998-08-04 00:00
First Revision of SSR Hardware mib.